MOBOTIX M10
M10-1-45-196 Enhanced Signal Out Options
Attribute
Value
Explanation
Signal Out Arming
Enable
Off
Activate Enhanced Signal Out
:
Enable
: activate Signal Out Action.
Off
: deactivate Signal Out Action.
Note: make sure to set
Signal Out Action
to
Off
.
Test signal out:
switch high
and
switch low
(no time table)
Weekdays_Mo-Fr
Weekend_Sa-So
Opening_Times
Closing_Times
MyCustomTimes
Time Table Profile
:
Time table profile for time-controlled signal out. (
Time Tables
)
Signal Out Switch Time
Switch Time
:
Switch Signal Output (pin 1-5) to High for [0..86000] seconds.
Signal Out Dead time
Dead Time
:
Timeout [0..3600 s] while detection is suspended.
Display Options
Show Event Symbols
:
Show Signal Out event symbols.
Illumination Filter
Illumination
Off
Greater
Less
Illumination Filter
:
Allow Signal Out actions, if illumination is greater/less than trigger level.
Level
:
Enter the level for illumination in lux.
Precision is one decimal digit.
Events for Signal Out
Passive Infrared Detector (PI)
PIR Enable
:
Motion detected by the infrared sensor.
PIR Level
:
Trigger level [0..100]
Video Motion Window (VM)
Video Motion Enable
:
Motion detection using digital image analysis.
Note:
parameters are taken from
Event Settings
.
Microphone (MI)
Microphone Enable
:
Noise detection using the internal microphone.
Note:
parameters are taken from
Event Settings
.
Signal Input (SI)
Signal Input
:
This event is triggered by an external signal (pin 9-5).
Select
Closed (low)
to trigger when loop connected to Signal Input is closed or
Open (high)
, when loop is opened.
Signal Input (pin 9-5)
CTS Signal (pin 8-5)
DSR Signal (pin 6-5)
RxD Signal (pin 2-5)
Signal Input Pin
:
Select input pin for this event.
(Requires
Data/IO-Mode
.)
Open (high)
Closed (low)
Rising (low to high)
Falling (high to low)
Change (Rising or Falling)
Trigger Condition
:
Select kind of trigger.
De-Bounce Time
:
De-Bounce time for signal input in ms [100..2000 ms].
Periodic Event (PE)
Periodic Event Enable
:
Trigger an action periodcally every x seconds.
Periodic Time Interval
:
Trigger interval [0..86400] in seconds
Time Task (TT)
Time Task
:
Trigger an event using a
Time Task
.
User Click (UC)
User Click
:
Triggers an event if the corresponding button on the camera's web site is clicked.
Click here to trigger a
User Click
.
Buttons (BT)
Buttons Enable
:
Trigger an event by pressing the button(s) on the front panel.
Right
Left
Right OR left
Right AND left
Button Combination
:
Select button(s) to trigger on.
IR Remote Control (IR)
Remote Control Enable
:
Trigger an event by signals from any IR remote control.
Note:
parameters are taken from
Event Settings
.
IP Receive (RC)
IP Receive Enable
:
Event on receiving a message over the network.
Note:
parameters are taken from
Event Settings
.
COM In (CI)
COM In Enable
:
Triggers an event when receiving a message from the serial interface. Set interface to
Data > Terminal and Logger mode
.
Note:
parameters are taken from
Event Settings
.
Temperature (TP)
Temperature Enable
:
Triggers an event if the temperature is higher/lower than the temperature value set below.
Note:
parameters are taken from
Event Settings
.
Random Event (RD)
Random Event Enable
:
Activate random events.
Random event is evaluated on every live image.
Events per Hour
:
Set random level in events per hour. Valid range from 0.0001 to 500.0000.
Precision is up to four digits.