Open camera homepageReturn to menu MOBOTIX M10  M10-1-45-196 Event Settings Open Help with keyword 'event-setting' Show Camera info
General Settings  Value  Explanation 
Event Dead Time Event Dead Time:
Event timeout [0..3600 s] while detection is suspended.
Events  Value  Explanation 
Passive Infrared Detector (PI)   PIR Enable:
Motion detected by the infrared sensor.
  PIR Level:
Trigger level [0..100]
Video Motion Window (VM)   Video Motion Enable:
Motion detection using digital image analysis.
  Video Motion Definitions (VM):
lens, x, y, width, height, sensitivity(0..99%), area(0..99%)[, max. area(0..99%)]
Origin: lower left corner
Lens: 0=right, 1=left
    Dual Lens Video Motion:
Detects Video Motion events on both lenses. May reduce the frame rate.
  Video Motion Style for Group 1:
Appearance of motion window border.
  Video Motion Night Mode:
Dark Video Motion Suppress:
Disables motion detection if illumination falls under selected value.
Video Motion Window (VM2)   Video Motion Enable:
Motion detection using digital image analysis.
  Video Motion Definitions (VM2):
lens, x, y, width, height, sensitivity(0..99%), area(0..99%)[, max. area(0..99%)]
Origin: lower left corner
Lens: 0=right, 1=left
    Dual Lens Video Motion:
Detects Video Motion events on both lenses. May reduce the frame rate.
  Video Motion Style for Group 2:
Appearance of motion window border.
  Video Motion Night Mode:
Dark Video Motion Suppress:
Disables motion detection if illumination falls under selected value.
Microphone (MI)   Microphone Enable:
Noise detection using the internal microphone.
  Microphone Level:
Trigger level [0..100]
  Microphone Signal Width:
Minimum duration of noises louder than trigger level.
Signal Input (SI)   Signal Input:
This event is triggered by an external signal (pin 9-5).
Select Closed (low) to trigger when loop connected to Signal Input is closed or Open (high), when loop is opened.
  Trigger Condition:
Select kind of trigger.
  De-Bounce Time:
De-Bounce time for signal input in ms [100..2000 ms].
Second Signal Input (SI2)   Second Signal Input:
This event is triggered by selected Signal Input Pin.
  Signal Input Pin:
Select input pin for this event.
(Requires Data/IO-Mode.)
  Trigger Condition:
Select kind of trigger.
  De-Bounce Time:
De-Bounce time for signal input in ms [100..2000 ms].
Third Signal Input (SI3)   Third Signal Input:
This event is triggered by selected Signal Input Pin.
  Signal Input Pin:
Select input pin for this event.
(Requires Data/IO-Mode.)
  Trigger Condition:
Select kind of trigger.
  De-Bounce Time:
De-Bounce time for signal input in ms [100..2000 ms].
Fourth Signal Input (SI4)   Fourth Signal Input:
This event is triggered by selected Signal Input Pin.
  Signal Input Pin:
Select input pin for this event.
(Requires Data/IO-Mode.)
  Trigger Condition:
Select kind of trigger.
  De-Bounce Time:
De-Bounce time for signal input in ms [100..2000 ms].
Periodic Event (PE)   Periodic Event Enable:
Trigger an action periodcally every x seconds.
  Periodic Time Unit:
Interval unit
  Periodic Time Interval:
Trigger interval [0..86400] in seconds, msec or Hz.
Time Task (TT) Time Task:
Trigger an event using a Time Task.
User Click (UC) User Click:
Triggers an event if the corresponding button on the camera's web site is clicked.
Click here to trigger a User Click.
Recording Begin (RB) Recording Begin:
Trigger an event if Recording starts.
Recording End (RE) Recording End:
Trigger an event if Recording ends.
Recording History (RH) Recording History:
Trigger an event if Recording saves a history image.
Recording Terminate (RT) Recording Terminate:
Trigger an event if the Terminate Recording function has stopped Recording.
Buttons (BT) Buttons Enable:
Trigger an event by pressing the button(s) on the front panel.
  Button Combination:
Select button(s) to trigger on.
IR Remote Control (IR)   Remote Control Enable:
Trigger an event by signals from any IR remote control.
  Remote Control Code:
IR code to receive for an event.
IP Receive (RC) IP Receive Enable:
Event on receiving a message over the network.
  IP Receive Port:
TCP port to listen on.
  IP Receive Compare:
Message match mode
  IP Receive Message:
Defines a message to wait for. Leave empty to trigger on any message.
  Comment Text Forwarding:
Enable forwarding of incoming and matching messages to comment text queue.
COM In (CI) COM In Enable:
Triggers an event when receiving a message from the serial interface. Set interface to Data > Terminal and Logger mode.
  COM In Compare:
Message match mode
  COM In Message:
Defines a message to wait for. Leave empty to trigger on any incoming message.
Temperature (TP) Temperature Enable:
Triggers an event if the temperature is higher/lower than the temperature value set below.
  Temperature Sensor:
Select the temperature sensor.
  Temperature Compare:
Select the trigger condition.
  Temperature Level:
Enter the temperature.
Precision is one decimal digit.
  Temperature Unit:
Select the temperature unit.
  Temperature Action:
Start action(s):
First: trigger only first time the condition is true.
Every: trigger every time the condition is true.
Illumination (IL) Illumination Enable:
Triggers an event if the illumination is higher/lower than the illumination value set below.
  Illumination Source:
Select the camera sensor for illumination.
  Illumination Compare:
Select the trigger condition.
  Illumination Level:
Enter the illumination in lux.
Precision is one decimal digit.
  Illumination Action:
Start action(s):
First: trigger only first time the condition is true.
Every: trigger every time the condition is true.
Random Event (RD) Random Event Enable:
Activate random events.
Random event is evaluated on every live image.
  Events per Hour:
Set random level in events per hour. Valid range from 0.0001 to 500.0000.
Precision is up to four digits.
Open Help with keyword 'event-setting'